Paint/Coating Equipment >
Adhesion Testers > Elcometer 1910
This lightweight, portable, hydraulic adhesion tester has built in hydraulic safety devices for smooth and drift proof accuracy.
The special test head allows adhesion tests on both internal and external curved surfaces, making this an ideal gauge for pipelines and protective coatings applications.
The Elcometer 1910 is supplied complete with a Calibration Certificate and:
- Crank handle driven pull mechanism
- PATT Testing Head 6.3kN (1416lbf)
- 5 Test Elements - 20mm (0.79") Diameter
- HSS Cutting Tool for 20mm (0.79") Diameter Test Elements
- Hydraulic Cable
- Carrying Case with Protective Interior
| ELCOMETER PAT RANGE SELECTION GUIDE AND TEST ELEMENTS |
| Element Number |
Test Element Diameter |
Range |
Range Values valid for the following Models |
Part Number |
| mm |
inches |
MPa |
PSI |
| TE001 |
2.3 |
0.09 |
160 |
23200 |
Elcometer 1930 |
KT001910P001 |
| TE002 |
4 |
0.16 |
80 |
11600 |
Elcometer 1930 |
KT001910P002 |
| TE003 |
5.7 |
0.22 |
40 |
5800 |
Elcometer 1930 |
KT001910P003 |
| TE004 |
8.16 |
0.32 |
120 |
17400 |
Elcometer 1910, 1920/1, 1940 |
KT001910P004 |
| TE005 |
14.1 |
0.55 |
40 |
5800 |
Elcometer 1910, 1920/1, 1940 |
KT001910P005 |
| TE006 |
20 |
0.79 |
20 |
2900 |
Elcometer 1910, 1920/1, 1940 |
KT001910P006 |
| TE007 |
25 |
0.98 |
40 |
5800 |
Elcometer 1920/1, 1940/1 |
KT001910P007 |
| TE008 |
25 |
0.98 |
80 |
11600 |
Elcometer 1920/3, 1940/2 |
KT001910P008 |
| TE009 |
25 |
0.98 |
160 |
23200 |
Elcometer 1920/4 |
KT001910P009 |
| TE010 |
28.5 |
1.11 |
10 |
1450 |
Elcometer 1910, 1920/1, 1940 |
KT001910P010 |
| TE011 |
40 |
1.57 |
5 |
725 |
Elcometer 1910, 1920/1, 1940 |
KT001910P011 |
| TE012 |
50 |
2.0 |
3.2 |
460 |
Elcometer 1920/1, 1940 |
KT001910P012 |
| TE013 |
50 |
2.0 |
10 |
1450 |
Elcometer 1920/2, 1941/1 |
KT001910P013 |
| TE014 |
50 |
2.0 |
20 |
2900 |
Elcometer 1920/3, 1941/2 |
KT001910P014 |
| TE015 |
50 |
2.0 |
40 |
7200 |
Elcometer 1920/4 |
KT001910P015 |
| TE016 |
50 x 50 |
2.0 x 2.0 |
7.85 |
1140 |
Elcometer 1920/2, 1941/1 |
KT001910P016 |
| TE017 |
50 x 50 |
2.0 x 2.0 |
15.7 |
2270 |
Elcometer 1920/3, 1941/2 |
KT001910P017 |
| TE018 |
70.7 |
2.78 |
5 |
725 |
Elcometer 1920/2, 1941/1 |
KT001910P018 |
| TE019 |
70.7 |
2.78 |
10 |
1450 |
Elcometer 1920/3, 1941/2 |
KT001910P019 |
| TE020 |
70.7 |
2.78 |
20 |
2900 |
Elcometer 1920/4 |
KT001910P020 |
| Maximum Pull Force |
6.3 kN |
Weight of Tester |
1250g (45oz) |
| Accuracy |
±1% of full scale |
Case Dimensions |
340 x 270 x 80mm (12 x 8 x 3") |
| Model |
Description |
Part Number |
| Elcometer 1910 |
Elcometer 1910 PAT Handyâ„¢ Adhesion Gauge |
K0001910M001 |
| Can be used in accordance with: |
| ASTM D 4541 |
EN 24624 |
| ISO 4624 |
Data Sheet
Please, click HERE to read it in PDF format in separate window. |
|
|